Most people choose attic roof windows for light, headroom and the view. Far fewer ask the question that matters most on the worst night of the year: if the stairs were full of smoke, could someone get out of this room through the window, or be reached by a ladder?

For attic conversions in Lucan, Bray and across Dublin, Wicklow and Kildare, that question has a specific answer in the Building Regulations guidance. A roof window that looks generous from the inside can still fail it because of how it opens, where it sits on the slope, or what kind of handle it has. This guide explains the figures in plain language so you can check them before the window is ordered and the roof is cut.

This is general information, not fire safety design advice. An attic conversion should be designed and certified by a competent building professional, and the fire safety details go well beyond the window.

Where the rules come from

Fire safety in homes is covered by Part B of the Building Regulations. The Department of Housing, Local Government and Heritage publishes Technical Guidance Document B, Fire Safety, Volume 2: Dwelling Houses (2017), which shows how to comply. The Department also publishes shorter Loft Conversion Guidelines aimed at homeowners, builders and designers.

TGD B treats a converted attic as an extra storey. Paragraph 1.3.6.5 and Appendix D say that:

  • a single-storey house (a bungalow) with a converted roof space should meet the provisions for houses with no floor more than 4.5 m above ground level (paragraph 1.3.2);
  • a two-storey house with a converted roof space should meet the provisions for houses with one floor more than 4.5 m above ground (paragraph 1.3.3), or the alternative loft conversion provisions in Appendix D, which can only be used where the new storey is no more than 50 m² and has no more than two habitable rooms.

Building Regulations apply whether or not the job needs planning permission.

Which rooms need an escape window?

As a general provision, paragraph 1.3.7.1 says all bedrooms in dwelling houses should have at least one window that meets the escape or rescue provisions, unless the bedroom has a door leading directly outside.

For loft conversions under Appendix D, paragraph D.4 goes further: the room or rooms in the new storey should each have an openable window or rooflight for escape or rescue that meets the relevant provisions of 1.3.7. So an attic "study" or "playroom" is not a way around it. If it is a habitable room in the new storey, it needs its own suitable window.

The figures your roof window has to meet

These are the provisions of TGD B paragraph 1.3.7.1 as they apply to a roof window or dormer in an attic room.

ItemWhat TGD B saysWhy it matters in practice
Clear open areaAt least 0.33 m², unobstructedMeasured through the open window, not the glass size or the frame size
Minimum dimensionsHeight not less than 450 mm and width not less than 450 mmA 450 x 450 mm opening is not enough on its own, because that is only about 0.2 m². Both the area and the minimum dimensions must be met
Staying openThe opening section should be capable of remaining in the position that gives the minimum clear areaA sash that swings back down on someone climbing out does not comply
Bottom of the openingNot more than 1100 mm above the floor and, for a rooflight, not less than 600 mmToo high and people cannot climb out. Too low and it becomes a fall risk in daily use
Distance from the eavesFor a dormer window or rooflight, not more than 1.7 m measured along the roof slope, from the eaves to the bottom of the opening section (or to the vertical plane of a dormer window)A window high up the slope leaves a long stretch of wet tiles between the person and a ladder
Outside, below the windowThe area beneath should make escape or rescue practicable. Where there is a clear drop from an attic conversion, the ground should be suitable for supporting a ladder safely and be accessible for rescueAn escape window above a glass conservatory or a locked, enclosed side passage is a problem
FasteningsReadily openable from the inside. Lockable handles or restrictors that can only be released by removable keys or tools should not be fittedKey-locking handles are a common mistake on replacement windows

One more detail surprises people. TGD K normally asks for guarding where a window cill is less than 800 mm above the floor. TGD B paragraph 1.3.7.1(c) makes an exception: guarding should not be provided to a rooflight opening that is there for escape or rescue. A bar across the escape window defeats its purpose.

Why the opening type matters as much as the size

The 0.33 m² is a clear, unobstructed area. How the sash moves decides whether you get it.

  • Centre-pivot windows rotate around the middle, so the sash stays in the opening and splits it in two. A large centre-pivot window can leave surprisingly little clear space to climb through.
  • Top-hung windows hinge at the top and swing outwards, which leaves the lower part of the opening clear. That is why they are the usual choice for escape positions.
  • Side-hung "access" style windows can also give a clear opening, depending on the model and size.

We are not quoting clear-opening figures for particular brands and size codes here, because they vary by model and should come from the manufacturer's current technical data for the exact window. Ask your supplier or installer to confirm in writing that the chosen model, in the chosen size, achieves at least 0.33 m² clear opening with 450 mm minimum height and width, and that it will stay open in that position. Our roof window brand comparison and guide to manual, electric and solar roof windows cover the wider choices.

Position on the roof: the part that is hard to fix later

Size can be corrected by swapping a window. Position cannot, at least not cheaply. Three measurements need to work together:

  1. Inside: the bottom of the opening lands between 600 mm and 1100 mm above the finished floor. Remember that the finished floor level in a conversion is higher than the old ceiling joists once new joists, insulation and flooring go in.
  2. Outside: the bottom of the opening section is within 1.7 m of the eaves, measured along the slope.
  3. Below: there is firm, accessible ground for a ladder.

On steep roofs in older Bray and Dublin City terraces, and on bungalows with deep roofs around Lucan, Celbridge and Naas, the window position that gives the best view from a standing height is often too far up the slope. It is better to find that out on a drawing than after the plasterboard is up.

The roof itself also limits where a window can go. Rafters, purlins, valleys, chimneys and the gutter line all affect the opening and the flashing. See our guide to roof checks before an attic conversion, and if the window faces the road, our post on front roof windows and planning exemptions.

The window is only one part of the fire strategy

For a two-storey house becoming three storeys, Appendix D of TGD B also covers, among other things:

  • enclosing the existing stairway in fire-resisting construction through to a final exit (D.2.1);
  • a new stairway to the attic that is separated from the new rooms by a self-closing fire door (D.2.2);
  • self-closing fire doors to habitable rooms and cupboards opening onto the stairway enclosure (D.2.3);
  • fire-resisting separation between the new storey and the rest of the house (D.2.5);
  • automatic smoke detection and alarms throughout the house (D.5).

An escape window does not replace any of these, and none of them replace the window. This is why the Department's guidelines recommend using a building professional to design, inspect and certify a conversion. That certification also matters when you sell: a room that does not comply is commonly described as "attic storage" rather than a bedroom.

Replacing a window in an existing attic room

Paragraph 1.3.7.2 says that where windows are being replaced in existing houses, bedroom windows should meet the escape provisions as far as is practicable, and that opening sections in other habitable rooms should not be reduced or altered in a way that reduces their potential for escape or rescue.

In practice, when an old roof window in an attic bedroom is being replaced:

  • do not swap a top-hung escape window for a centre-pivot one of the same size just because it is cheaper;
  • do not add key-locking handles or keyed restrictors;
  • consider whether the replacement is a chance to improve a window that never met the figures.

Our guide to replacing an old Velux by size code explains how to identify what is fitted now.

A checklist before you order

  • Has your designer confirmed which TGD B route the conversion follows (1.3.2, 1.3.3 or Appendix D)?
  • Does every habitable attic room have its own escape window?
  • Has the supplier confirmed the clear opening area and minimum dimensions for the exact model and size?
  • Does the window stay open on its own at that position?
  • Is the bottom of the opening 600 to 1100 mm above the finished floor?
  • Is it within 1.7 m of the eaves along the slope?
  • Is the handle free of key locks and keyed restrictors?
  • Is there safe, accessible ground below for a ladder, with no conservatory or lean-to roof in the way unless it can take the load?
  • Does everyone in the house know which window it is and how it opens?

Safety

Please do not climb onto the roof or lean out of a roof window to measure the distance to the eaves. The measurements can be taken from inside the attic and from drawings, and a roofer can confirm them safely during a site visit.

Talk to Perfect Roofing

We install and replace roof windows across Dublin City, North Dublin, South Dublin, Lucan, Bray, Wicklow, Naas and nearby areas. If you are planning an attic room, we can check the roof, advise on window positions that suit the rafters and roof covering, and work with your designer so the escape window is right before the opening is cut.

Contact us by WhatsApp, call 083 066 3462, or email hi@perfectroofing.ie.

Roofs, gutters, and Velux windows

Need a roofer to take a look?

Send a few photos on WhatsApp, email us, or tap the number to call. We cover Dublin City, North Dublin, South Dublin, Lucan, Bray, Wicklow, Naas, and nearby locations.

Related Articles

Discover more insights about roofing and home maintenance